A WNDAP360 can be in Standalone mode , or it can be managed by a Wireless Controller.
If you want to change the type ( Managed to Standalone mode ) you need to flash the device firmware. Performing a Factory Reset ( Holding down Reset Button ) just resets the WebGui Login password.
Firmware upgrade sequence for WNDAP360 from 2.x:
V2.1.11 -> V2.1.12 -> V3.5.20.0 – Correct sequence.
Download the Firmwares from here :
https://www.netgear.com/support/product/WNDAP360.aspx#download
See – View Previous Versions
Once Download . UnZip the .tar files !
Login to the webportal of the managed WNDAP360 and upload the first V2.1.11 Firmware (.tar ) ( I used Chrome )
What you will see in the console serial cable connection , is the device restart straight away then wait on the below , Leave the webbrowser open
######################### Start SysMon Entity [30] #########################
# Name=RFID Mgr, Path=/ft/bin/rfid_mgr, Type=0
######################### Start SysMon Entity [31] #########################
# Name=RFID Serial Comm, Path=/ft/bin/rfid_serial_comm, Type=0
Executing file /FT_CONF/prepare_upgrade
********* Waiting for Upgrade file *********
Wait on this screen for a few minutes
Netgear mips #1 Tue Dec 6 11:52:49 IST 2016 (none)
Netgear login:
FACDEF_DRV: Disabling watchdog
TERM
You should then see it formating the file system and rebooting again
Once ready you can go upload V2.1.12 ( takes a while as it has to encrypt the filesystem )
Then V3.5.20.0 and whatever’s the latest!